PHOENIX 250 - 1200 VA

Inversor- senoidal-Phoenix-inverter-12/1200.jpg

VE.Direct communication port:

The VE.Direct port can be connected to:

• A computer (a VE.Direct to USB interface cable is needed)

• Apple and Android smartphones, tablets, MacBooks, and other devices (a VE.Direct to Bluetooth Smart adapter is needed)

Fully configurable:

• Alarm trigger and reset levels for low battery voltage.

• Disconnect and restart levels for low battery voltage.

• Dynamic disconnection: disconnection level dependent on load

• Output voltage 210 – 245 V

• Frequency 50 Hz or 60 Hz

• On/off for ECO mode and level sensor for ECO mode

Monitoring:

• Input/output voltage and current, % load and alarms www.victronenergy.com

Proven reliability

The full bridge topology plus toroidal transformer has proven its reliability over many years. The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.

High starting power

Necessary to start loads such as converters for LED lamps, halogen lamps, or power tools.

ECO mode

In ECO mode, the inverter will go into standby when the load drops below a preset value (minimum load: 15 W). Once in standby, the inverter will activate briefly (adjustable; default: every 2.5 seconds). If the load exceeds the preset level, the inverter will remain on.

Remote on/off switch

A remote On/Off switch can be connected to a two-phase connector or between the battery positive terminal and the left contact of the two-phase connector.

LED Diagnostics

Please refer to the manual for its description.

To transfer the load to another AC source: the automatic transfer switch

For our lower power inverters, we recommend our Filax automatic transfer switch. The switching time of the "Filax" is very short (less than 20 milliseconds), so that computers and other electronic devices will continue to operate without interruption.

 

12/180

24/180

12/350

24/350

48/350

12/800

24/800

48/800

12/1200

24/1200

48/1200

Especificaciones eléctricas
Continuous AC power at  25 ºC 180 VA 350 VA 800 VA 1200 VA
Continuous Power at 25/40 ºC 175 / 150 W 300 / 250 W 700 / 650 W 1000 / 900 W
Peak power 350 W 700 W 1600 W 2400 W
Output voltage 230 Vca ±3% (110 Vca ±3%)
Output frecuency 50 Hz ±0,1 % (60 Hz ±0,1 %)
Wave form Sine Wave
Max. Efficiency 12/24/48 V 87 /88 % 89 / 89 / 90 % 91 / 93 / 94 % 92 / 92 / 94 %
Zero Load Power 12/24/48 V 2,6 / 3,8 W 3,1 / 5,0 / 6,0 W 6 / 6 / 6 W 8 / 9 / 8 W
Input voltage range 10,5 - 11,5 / 21,0 - 31,0 / 42,0 - 62,0 Vdc 9,2 - 17,3 / 18,4 - 34,0 / 36,8 - 68,0 Vdc
Low battery alarm 11 / 22 / 44 Vdc 10,9 / 21,8 / 43,6 Vdc
Low battery shut down 10,5 / 21 / 42 Vdc 9,2 / 18,4 / 43,6 Vdc
Low battery auto recovery 12,5 / 25 / 50 Vdc 12,5 / 25 / 50 Vdc
Protections Output short circuit / battery voltage too low
General specifications
Operating temperature range -40 to 50 ºC
Standard AC outlets Schuko / IEC / Nema
Battery connection

Cigarette plug

1,5 mts. cable 1,5 mts. cable 1,5 mts. cable
Protection category IP20 IP20 IP20 IP20
Dimensions 72 x 132 x 200 mm 72 x 155 x 237 mm 104 x 194 x 305 mm 104 x 194 x 305 mm
Weight 2,7 Kgr 3,5 Kgr 6,5 Kgr 8,5 Kgr

 

  • Inversor- senoidal-Phoenix-inverter-12/1200.jpg
  • Inversor-12v-Victron-Energy-Phoenix.jpg
  • Inversor-Senoidal-Victron-Energy-Phoenix.jpg