PHOENIX 250 - 1200 VA

VE.Direct communication port:
The VE.Direct port can be connected to:
• A computer (a VE.Direct to USB interface cable is needed)
• Apple and Android smartphones, tablets, MacBooks, and other devices (a VE.Direct to Bluetooth Smart adapter is needed)
Fully configurable:
• Alarm trigger and reset levels for low battery voltage.
• Disconnect and restart levels for low battery voltage.
• Dynamic disconnection: disconnection level dependent on load
• Output voltage 210 – 245 V
• Frequency 50 Hz or 60 Hz
• On/off for ECO mode and level sensor for ECO mode
Monitoring:
• Input/output voltage and current, % load and alarms www.victronenergy.com
Proven reliability
The full bridge topology plus toroidal transformer has proven its reliability over many years. The inverters are short-circuit proof and protected against overheating, whether due to overload or high ambient temperature.
High starting power
Necessary to start loads such as converters for LED lamps, halogen lamps, or power tools.
ECO mode
In ECO mode, the inverter will go into standby when the load drops below a preset value (minimum load: 15 W). Once in standby, the inverter will activate briefly (adjustable; default: every 2.5 seconds). If the load exceeds the preset level, the inverter will remain on.
Remote on/off switch
A remote On/Off switch can be connected to a two-phase connector or between the battery positive terminal and the left contact of the two-phase connector.
LED Diagnostics
Please refer to the manual for its description.
To transfer the load to another AC source: the automatic transfer switch
For our lower power inverters, we recommend our Filax automatic transfer switch. The switching time of the "Filax" is very short (less than 20 milliseconds), so that computers and other electronic devices will continue to operate without interruption.
Specifications
12/180 24/180 |
12/350 24/350 48/350 |
12/800 24/800 48/800 |
12/1200 24/1200 48/1200 |
|
Especificaciones eléctricas | ||||
Continuous AC power at 25 ºC | 180 VA | 350 VA | 800 VA | 1200 VA |
Continuous Power at 25/40 ºC | 175 / 150 W | 300 / 250 W | 700 / 650 W | 1000 / 900 W |
Peak power | 350 W | 700 W | 1600 W | 2400 W |
Output voltage | 230 Vca ±3% (110 Vca ±3%) | |||
Output frecuency | 50 Hz ±0,1 % (60 Hz ±0,1 %) | |||
Wave form | Sine Wave | |||
Max. Efficiency 12/24/48 V | 87 /88 % | 89 / 89 / 90 % | 91 / 93 / 94 % | 92 / 92 / 94 % |
Zero Load Power 12/24/48 V | 2,6 / 3,8 W | 3,1 / 5,0 / 6,0 W | 6 / 6 / 6 W | 8 / 9 / 8 W |
Input voltage range | 10,5 - 11,5 / 21,0 - 31,0 / 42,0 - 62,0 Vdc | 9,2 - 17,3 / 18,4 - 34,0 / 36,8 - 68,0 Vdc | ||
Low battery alarm | 11 / 22 / 44 Vdc | 10,9 / 21,8 / 43,6 Vdc | ||
Low battery shut down | 10,5 / 21 / 42 Vdc | 9,2 / 18,4 / 43,6 Vdc | ||
Low battery auto recovery | 12,5 / 25 / 50 Vdc | 12,5 / 25 / 50 Vdc | ||
Protections | Output short circuit / battery voltage too low | |||
General specifications | ||||
Operating temperature range | -40 to 50 ºC | |||
Standard AC outlets | Schuko / IEC / Nema | |||
Battery connection |
Cigarette plug |
1,5 mts. cable | 1,5 mts. cable | 1,5 mts. cable |
Protection category | IP20 | IP20 | IP20 | IP20 |
Dimensions | 72 x 132 x 200 mm | 72 x 155 x 237 mm | 104 x 194 x 305 mm | 104 x 194 x 305 mm |
Weight | 2,7 Kgr | 3,5 Kgr | 6,5 Kgr | 8,5 Kgr |
Do you want more information about this product?
bornay@bornay.com | (+34) 965 560 025 | Skype