PHOENIX VE.DIRECT INVERTERS

Inversor-phoenix-vedirect.jpg Inversor Phoenix VE.Direct
Inversor-Victron-Energy-phoenix-vedirec-1.jpg Inversor Victron Energy Phoenix VE.Direct
Inversor-phoenix-vedirect-2.jpg Inversor Phoenix VE.Direct
ve.direct-ios.jpg VE.Direct IOS
bluethooth-dongle.jpg VE.Direct Bluethooth dongle

The new serie of Victron Energy Phoenix VE.Direct inverters comes to replace the well know Phoenix inverters, including new functionalities and versatility to this product:

VE.Direct communication port

The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, macbooks and other devices (VE.Direct Bluetooth Smart dongle needed)

Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Output voltage 210 - 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level

Monitoring:
• In- and output voltage and current alarms

Proven reliability

The full bridge plus toroidal transformer topology has proven its reliability over many years.

The inverters are short circuit proof and protected against overheating, whether due to overload or high ambient temperature.

High start-up power

Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.

ECO mode

When in ECO mode, the inverter will switch to standby when the load decreases below a preset value. Once in standby the inverter will switch on for a short period (adjustable, default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on.

Remote on/off

A remote on/off switch can be connected to a two pole connector, or between battery plus and the left hand contact of the two pole connector.

LED diagnosis

Now you can get information of the inverter status thanks to the leds. Please see manual for a description.

To transfer the load to another AC source: the automatic transfer switch

For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features a very short switchover time (less than 20 milliseconds) so that computers and other electronic equipment will continue to operate without disruption.

Available with different output sockets

Schuko
UK (BS-1363)
AU/NZ (3112)
IEC-320 (male plug included)

Screw terminals

No special tools needed for installation

Specifications

  12/250 - 24/250 - 48/250 12/375 - 24/375 - 48/375
Cont. Power 25º C 250 VA 375 VA
Cont. Power at 25 / 40º C 200 / 150 W 300 / 250 W
Peak Power 350 W 700 W
Output AC voltage 230 Vac +/- 3%
Output Frequency 50 or 60 Hz (adjustable) +/- 0,1%
Input voltage range 12v: 9,2 - 17 vdc / 24v: 18,4 - 34 Vdc / 48v: 36,8 - 62 Vdc
DC low shut down 9,3 / 18,6 / 37,2 Vdc (adjustable)
DC low restart and alarm 10,9 / 21,8 / 43,6 Vdc (adjustable)
Battery charged detect 14 / 28 / 56 Vdc (adjustable)
Max. eficiency 87 / 88 / 88 % 89 / 89 / 90 %
Zero-load consumption 4,2 / 5,2 / 7,9 W 5,6 / 6,1 / 8,5 W
ECO mode consumption 0,8 / 1,3 / 2,5 W 0,9 / 1,4 / 2,6 W
ECO mode interval 2,5 s. (adjustable)
Protectión

Output short circuit

Overload

Battery voltage too hight

Battery voltage too low

Temperature too high

DC ripple too high

Temperature -40 to +60 ºC (fan assisted cooling) Derate 3% per ºC above 40 ºC
Humidity max 95 % (non.condensing)
Enclosure    
Material & Colour Stell chassis and plastic cover (Blue RAL 5012)
Battery-connection Screw terminals
Maximum cable cross-section 10 mm2 10 mm2
IP Protection IP21
weight 2,4 Kg 3,0 Kg
Dimensions 86 x 165 x 260 mm 86 x 165 x 260 mm
Standards    
Safety EN/IEC 60335*1 / EN/IEC 62109-1
EMC EN 55014-1 / EN55014-2 / EN 61000-6-1 / IEC 61000-6-3
Automotive directive 2004/104/EC     EN 50498