POWER OPTIMIZIER

The SolarEdge module add-on power optimizer is connected by installers to the solar modules. Ease of installation is completed by simply clipping the power optimizer to the module frame or by attaching it to the rail with a single screw.
SolarEdge-Optimizador-1.jpg SolarEdge Optimizador
SolarEdge-Optimizador-2.jpg SolarEdge Optimizador
SolarEdge-Optimizador-3.jpg SolarEdge Optimizador

P-Series Module Add-On Power Optimizers

Connected by installers to the PV module and compatible with a wide range of modules

Power Optimizer P Model Module Power Module Voc
P300 ≤ 300 W < 48 V
P350 ≤ 350 W < 60 V
P500 ≤ 500 W < 80 V
P404 ≤ 405 W < 80 V
P405 ≤ 405 W < 125 V

 

 

 

 

 

 

 

* Also available with frames mounted in advance for quicker installation.

 

 

P-Series Commercial Power Optimizer

Commercial solution connecting two modules per power optimizer

Power Optimizer Model Module Power Module Voc
P600 ≤600W* < 96 V
P700 ≤700W* < 125 V

 

* Rated combined STC power of 2 modules connected in series. Module of up to +5% power tolerance allowed.

* Also available with frames mounted in advance for quicker installation.

 

Feature highlights:

  • Per-module Maximum Power Point Tracking (MPPT)
  • Superior efficiency (99.5% peak efficiency, 98.8% weighted efficiency) 
  • Mitigates all  types of modules mismatch-loss, from manufacturing tolerance to partial shading             
  • Designed for extreme environmental conditions
  • 25 year reliability and warranty
  • Advanced, real-time performance measurement
  • Automatic module DC voltage shut-down for installer and firefighter safety
  • Independent optimization technology (IndOP™) - allows operation with any inverter and requires no additional interface hardware 
  • Available with frames mounted in advance for quicker installation

 

SolarEdge, Typical grid connection System

Spedifications

 

    P300 P350 P500 P404 P405 P600 P700
    60 cell 60/72 cell 96 cell 60/72 cell Thin Film 2 x 60 cell 2 x 72 cell
INPUT
Rated Input DC Power (1) W 300 350 500 405 405 600 700
Absolute Maximum Input Voltage
(Voc at lowest temperature)
Vdc 48 60 80 80 125 96 125
MPPT Operating Range Vdc 8 - 48 8 - 60 8 - 80 12,5 - 80 12,5 - 105 12,5 - 80 12,5 - 105
Maximum Continuous Input Current (Isc) Adc 10 11 10,1
Maximum Efficiency % 99,5
Weighted Efficiency % 98,8
Overtoltage Category   II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)
Maximum Output Current Adc 15
Maximum Output Voltage Vdc 60 85
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)
Safety Output Voltage per Power Optimizer Vdc 1
STANDARD COMPLIANCE
EMC   FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3
Safety   IEC62109-1 (class II safety), UL1741
RoHS   Yes
Fire Safety   VDE-AR-E 2100-712:2013-05
INSTALLATION SPECIFICATIONS
Compatible SolarEdge Inverters   Single Phase 3 phases
Maximum Allowed System Voltage Vdc 1000
Dimensions (W x L x H) mm 128 x 152 x 27,5 128 x 152 x 35 128 x 152 x 43 128 x 152 x 50 139 x 165 x 56 139 x 165 x63
Weight (including cables) gr 760 830 994 1064 1065 1185
Input Connector   MC4 (2)
Output Connector   MC4
Output Wire Length m 0,95 1,2 1,8 2,1
Operating Temperature Range º C -40 +85
Protection Rating   IP68 / NEMA6P
Relative Humidity % 0 - 100

 

(1) Rated STC power of the module. Module of up to +5% power tolerance allowed.
(2) For other connector types please contact SolarEdge.
(3) For ambient temperature above +70˚C / +158˚F power de-rating is applied. Refer to “Power Optimizers Temperature De-Rating Application Note” for more details.

 

PV SYSTEM DESIGN (4)(5)

Single Phase

Three phases

SE15K & larger
 

Three phases

SE16K & larger
 

Three phases

SE33.3K
 

Minimum String Length
(Power Optimizers)
P300, P350, P500 8 16 16 16
P404, P405 6 13 13 13
P600 - 13 (26 modules) 13 (26 modules) 13 (26 modules)
P700 - - 13 (26 modules) 13 (26 modules)

Maximum String Length

(Power Optimizers)

P300, P350, P500, P404, P500 25 50 50 50
P600, P700 - 30 (60 modules) 30 (60 modules) 30 (60 modules)
Maximum Power per String 5.250 W 11.250 W 11.250 W (6) 12.750 W (7)
Parallel Strings of Different Lengths or Orientations

 

(4) It is not allowed to mix P404/P405 with P300/P350/P500/P600/P700 in one string..
     It is not allowed to mix P600/P700 with P300/P350/P404/P405/P500 in one string
     P600 and P700 can be mixed in one string.
(5) In a case of odd number of PV Modules in one string it is allowed to install one P600/P700 power optimizer connected to one PV Module.
(6) For SE27.6K: It is allowed to install up to 13,500W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 37,250W.
(7) PFor SE33.3K: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 45,000W.